Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 72
Filtrar
1.
Emerg Radiol ; 2024 Apr 18.
Artigo em Inglês | MEDLINE | ID: mdl-38632154

RESUMO

PURPOSE: To investigate the effects of mid-inspiratory respiration commands and other factors on transient interruption of contrast (TIC) incidence on CT pulmonary angiography. METHODS: In this retrospective study, 824 patients (mean age, 66.1 ± 15.3 years; 342 males) who had undergone CT pulmonary angiography between January 2021 and February 2023 were included. Among them, 545 and 279 patients were scanned at end- and mid-inspiratory levels, respectively. By placing a circular region of interest, CT attenuation of the main pulmonary artery (CTMPA) was recorded. Associations between several factors, including patient age, body weight, sex, respiratory command vs. TIC and severe TIC incidence (defined as CTMPA < 200 and 150 HU, respectively), were assessed using logistic regression analyses with stepwise regression selection based on Akaike's information criterion. RESULTS: Mid-inspiratory respiration command, in addition to patient age and lighter body weight, had negative association with the incidence of TIC. Only patient age, lighter body weight, female sex, and larger cardiothoracic ratio were negatively associated with severe TIC incidence. Mid-inspiratory respiration commands helped reduce TIC incidence among patients aged < 65 years (p = 0.039) and those with body weight ≥ 75 kg (p = 0.005) who were at high TIC risk. CONCLUSION: Changing the respiratory command from end- to mid-inspiratory levels, as well as patient age and body weight, was significantly associated with TIC incidence.

2.
J Imaging Inform Med ; 2024 Mar 06.
Artigo em Inglês | MEDLINE | ID: mdl-38448759

RESUMO

This study aimed to investigate the effects of intravenous injection of iodine contrast agent on the tracheal diameter and lung volume. In this retrospective study, a total of 221 patients (71.1 ± 12.4 years, 174 males) who underwent vascular dynamic CT examination including chest were included. Unenhanced, arterial phase, and delayed-phase images were scanned. The tracheal luminal diameters at the level of the thoracic inlet and both lung volumes were evaluated by a radiologist using a commercial software, which allows automatic airway and lung segmentation. The tracheal diameter and both lung volumes were compared between the unenhanced vs. arterial and delayed phase using a paired t-test. The Bonferroni correction was performed for multiple group comparisons. The tracheal diameter in the arterial phase (18.6 ± 2.4 mm) was statistically significantly smaller than those in the unenhanced CT (19.1 ± 2.5 mm) (p < 0.001). No statistically significant difference was found in the tracheal diameter between the delayed phase (19.0 ± 2.4 mm) and unenhanced CT (p = 0.077). Both lung volumes in the arterial phase were 4131 ± 1051 mL which was significantly smaller than those in the unenhanced CT (4332 ± 1076 mL) (p < 0.001). No statistically significant difference was found in both lung volumes between the delayed phase (4284 ± 1054 mL) and unenhanced CT (p = 0.068). In conclusion, intravenous infusion of iodine contrast agent transiently decreased the tracheal diameter and both lung volumes.

3.
Neuroradiology ; 2024 Mar 22.
Artigo em Inglês | MEDLINE | ID: mdl-38514472

RESUMO

PURPOSE: We investigated whether the quality of high-resolution computed tomography (CT) images of the temporal bone improves with deep learning reconstruction (DLR) compared with hybrid iterative reconstruction (HIR). METHODS: This retrospective study enrolled 36 patients (15 men, 21 women; age, 53.9 ± 19.5 years) who had undergone high-resolution CT of the temporal bone. Axial and coronal images were reconstructed using DLR, HIR, and filtered back projection (FBP). In qualitative image analyses, two radiologists independently compared the DLR and HIR images with FBP in terms of depiction of structures, image noise, and overall quality, using a 5-point scale (5 = better than FBP, 1 = poorer than FBP) to evaluate image quality. The other two radiologists placed regions of interest on the tympanic cavity and measured the standard deviation of CT attenuation (i.e., quantitative image noise). Scores from the qualitative and quantitative analyses of the DLR and HIR images were compared using, respectively, the Wilcoxon signed-rank test and the paired t-test. RESULTS: Qualitative and quantitative image noise was significantly reduced in DLR images compared with HIR images (all comparisons, p ≤ 0.016). Depiction of the otic capsule, auditory ossicles, and tympanic membrane was significantly improved in DLR images compared with HIR images (both readers, p ≤ 0.003). Overall image quality was significantly superior in DLR images compared with HIR images (both readers, p < 0.001). CONCLUSION: Compared with HIR, DLR provided significantly better-quality high-resolution CT images of the temporal bone.

4.
Can Assoc Radiol J ; : 8465371241228468, 2024 Jan 31.
Artigo em Inglês | MEDLINE | ID: mdl-38293802

RESUMO

Objective: This study aimed to investigate whether deep-learning reconstruction (DLR) improves interobserver agreement in the evaluation of honeycombing for patients with interstitial lung disease (ILD) who underwent high-resolution computed tomography (CT) compared with hybrid iterative reconstruction (HIR). Methods: In this retrospective study, 35 consecutive patients suspected of ILD who underwent CT including the chest region were included. High-resolution CT images of the unilateral lung with DLR and HIR were reconstructed for the right and left lungs. A radiologist placed regions of interest on the lung and measured standard deviation of CT attenuation (i.e., quantitative image noise). In the qualitative image analyses, 5 blinded readers assessed the presence of honeycombing and reticulation, qualitative image noise, artifacts, and overall image quality using a 5-point scale (except for artifacts which was evaluated using a 3-point scale). Results: The quantitative and qualitative image noise in DLR was remarkably reduced compared to that in HIR (P < .001). Artifacts and overall DLR quality were significantly improved compared to those of HIR (P < .001 for 4 out of 5 readers). Interobserver agreement in the evaluations of honeycombing and reticulation for DLR (0.557 [0.450-0.693] and 0.525 [0.470-0.541], respectively) were higher than those for HIR (0.321 [0.211-0.520] and 0.470 [0.354-0.533], respectively). A statistically significant difference was found for honeycombing (P = .014). Conclusions: DLR improved interobserver agreement in the evaluation of honeycombing in patients with ILD on CT compared to HIR.

5.
Neuroradiology ; 66(3): 371-387, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38236423

RESUMO

PURPOSE: To investigate the effects on tractography of artificial intelligence-based prediction of motion-probing gradients (MPGs) in diffusion-weighted imaging (DWI). METHODS: The 251 participants in this study were patients with brain tumors or epileptic seizures who underwent MRI to depict tractography. DWI was performed with 64 MPG directions and b = 0 s/mm2 images. The dataset was divided into a training set of 191 (mean age 45.7 [± 19.1] years), a validation set of 30 (mean age 41.6 [± 19.1] years), and a test set of 30 (mean age 49.6 [± 18.3] years) patients. Supervised training of a convolutional neural network was performed using b = 0 images and the first 32 axes of MPG images as the input data and the second 32 axes as the reference data. The trained model was applied to the test data, and tractography was performed using (a) input data only; (b) input plus prediction data; and (c) b = 0 images and the 64 MPG data (as a reference). RESULTS: In Q-ball imaging tractography, the average dice similarity coefficient (DSC) of the input plus prediction data was 0.715 (± 0.064), which was significantly higher than that of the input data alone (0.697 [± 0.070]) (p < 0.05). In generalized q-sampling imaging tractography, the average DSC of the input plus prediction data was 0.769 (± 0.091), which was also significantly higher than that of the input data alone (0.738 [± 0.118]) (p < 0.01). CONCLUSION: Diffusion tractography is improved by adding predicted MPG images generated by an artificial intelligence model.


Assuntos
Inteligência Artificial , Imagem de Difusão por Ressonância Magnética , Humanos , Pessoa de Meia-Idade , Adulto , Imagem de Difusão por Ressonância Magnética/métodos , Imagem de Tensor de Difusão/métodos , Imageamento por Ressonância Magnética , Redes Neurais de Computação , Processamento de Imagem Assistida por Computador/métodos
6.
Can Assoc Radiol J ; 75(1): 74-81, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37387607

RESUMO

Purpose: We investigated the effect of deep learning reconstruction (DLR) plus single-energy metal artifact reduction (SEMAR) on neck CT in patients with dental metals, comparing it with DLR and with hybrid iterative reconstruction (Hybrid IR)-SEMAR. Methods: In this retrospective study, 32 patients (25 men, 7 women; mean age: 63 ± 15 years) with dental metals underwent contrast-enhanced CT of the oral and oropharyngeal regions. Axial images were reconstructed using DLR, Hybrid IR-SEMAR, and DLR-SEMAR. In quantitative analyses, degrees of image noise and artifacts were evaluated. In one-by-one qualitative analyses, 2 radiologists evaluated metal artifacts, the depiction of structures, and noise on five-point scales. In side-by-side qualitative analyses, artifacts and overall image quality were evaluated by comparing Hybrid IR-SEMAR with DLR-SEMAR. Results: Artifacts were significantly less with DLR-SEMAR than with DLR in quantitative (P < .001) and one-by-one qualitative (P < .001) analyses, which resulted in significantly better depiction of most structures (P < .004). Artifacts in side-by-side analysis and image noise in quantitative and one-by-one qualitative analyses (P < .001) were significantly less with DLR-SEMAR than with Hybrid IR-SEMAR, resulting in significantly better overall quality of DLR-SEMAR. Conclusions: Compared with DLR and Hybrid IR-SEMAR, DLR-SEMAR provided significantly better supra hyoid neck CT images in patients with dental metals.


Assuntos
Artefatos , Aprendizado Profundo , Masculino , Humanos , Feminino , Pessoa de Meia-Idade , Idoso , Estudos Retrospectivos , Processamento de Imagem Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Algoritmos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Doses de Radiação
7.
Neuroradiology ; 66(1): 63-71, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37991522

RESUMO

PURPOSE: This study aimed to investigate the impact of deep learning reconstruction (DLR) on acute infarct depiction compared with hybrid iterative reconstruction (Hybrid IR). METHODS: This retrospective study included 29 (75.8 ± 13.2 years, 20 males) and 26 (64.4 ± 12.4 years, 18 males) patients with and without acute infarction, respectively. Unenhanced head CT images were reconstructed with DLR and Hybrid IR. In qualitative analyses, three readers evaluated the conspicuity of lesions based on five regions and image quality. A radiologist placed regions of interest on the lateral ventricle, putamen, and white matter in quantitative analyses, and the standard deviation of CT attenuation (i.e., quantitative image noise) was recorded. RESULTS: Conspicuity of acute infarct in DLR was superior to that in Hybrid IR, and a statistically significant difference was observed for two readers (p ≤ 0.038). Conspicuity of acute infarct with time from onset to CT imaging at < 24 h in DLR was significantly improved compared with Hybrid IR for all readers (p ≤ 0.020). Image noise in DLR was significantly reduced compared with Hybrid IR with both the qualitative and quantitative analyses (p < 0.001 for all). CONCLUSION: DLR in head CT helped improve acute infarct depiction, especially those with time from onset to CT imaging at < 24 h.


Assuntos
Aprendizado Profundo , Masculino , Humanos , Estudos Retrospectivos , Infarto Encefálico , Encéfalo , Tomografia Computadorizada por Raios X , Interpretação de Imagem Radiográfica Assistida por Computador , Doses de Radiação , Algoritmos
8.
J Comput Assist Tomogr ; 47(6): 996-1001, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37948377

RESUMO

OBJECTIVE: Magnetic resonance imaging (MRI) is commonly used to evaluate cervical spinal canal stenosis; however, some patients are ineligible for MRI. We aimed to assess the effect of deep learning reconstruction (DLR) in evaluating cervical spinal canal stenosis using computed tomography (CT) compared with hybrid iterative reconstruction (hybrid IR). METHODS: This retrospective study included 33 patients (16 male patients; mean age, 57.7 ± 18.4 years) who underwent cervical spine CT. Images were reconstructed using DLR and hybrid IR. In the quantitative analyses, noise was recorded by placing the regions of interest on the trapezius muscle. In the qualitative analyses, 2 radiologists evaluated the depiction of structures, image noise, overall image quality, and degree of cervical canal stenosis. We additionally evaluated the agreement between MRI and CT in 15 patients for whom preoperative cervical MRI was available. RESULTS: Image noise was less with DLR than hybrid IR in the quantitative ( P ≤ 0.0395) and subjective analyses ( P ≤ 0.0023), and the depiction of most structures was improved ( P ≤ 0.0052), which resulted in better overall quality ( P ≤ 0.0118). Interobserver agreement in the assessment of spinal canal stenosis with DLR (0.7390; 95% confidence interval [CI], 0.7189-0.7592) was superior to that with hybrid IR (0.7038; 96% CI, 0.6846-0.7229). As for the agreement between MRI and CT, significant improvement was observed for 1 reader with DLR (0.7910; 96% CI, 0.7762-0.8057) than hybrid IR (0.7536; 96% CI, 0.7383-0.7688). CONCLUSIONS: Deep learning reconstruction provided better quality cervical spine CT images in the evaluation of cervical spinal stenosis than hybrid IR.


Assuntos
Aprendizado Profundo , Estenose Espinal , Humanos , Masculino , Adulto , Pessoa de Meia-Idade , Idoso , Estenose Espinal/diagnóstico por imagem , Estudos Retrospectivos , Constrição Patológica , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Canal Medular , Algoritmos , Doses de Radiação
9.
Can Assoc Radiol J ; : 8465371231203508, 2023 Oct 05.
Artigo em Inglês | MEDLINE | ID: mdl-37795610

RESUMO

PURPOSE: To compare the impact of deep learning reconstruction (DLR) and hybrid-iterative reconstruction (hybrid-IR) on vertebral mass depiction, detection, and diagnosis of spinal cord compression on computed tomography (CT). METHODS: This retrospective study included 29 and 20 patients with and without vertebral masses. CT images were reconstructed using DLR and hybrid-IR. Three readers performed vertebral mass detection tests and evaluated the presence of spinal cord compression, the depiction of vertebral masses, and image noise. Quantitative image noise was measured by placing regions of interest on the aorta and spinal cord. RESULTS: Deep learning reconstruction tended to improve the performance of readers with less diagnostic imaging experience in detecting vertebral masses (area under the receiver operating characteristic curve [AUC] = .892-.966) compared with hybrid-IR (AUC = .839-.917). Diagnostic performance in evaluating spinal cord compression in DLR (AUC = .887-.995) also improved compared with that in hybrid-IR (AUC = .866-.942) for some readers. The depiction of vertebral masses and subjective image noise in DLR were significantly improved compared with those in hybrid-IR (P < .041). Quantitative image noise in DLR was also significantly reduced compared with that in hybrid-IR (P < .001). CONCLUSION: Deep learning reconstruction improved the depiction of vertebral masses, which resulted in a tendency to improve the performance of CT compared to hybrid-IR in detecting vertebral masses and diagnosing spinal cord compression for some readers.

10.
Neuroradiology ; 65(10): 1473-1482, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37646791

RESUMO

PURPOSE: To compare the diagnostic performance of 1.5 T versus 3 T magnetic resonance angiography (MRA) for detecting cerebral aneurysms with clinically available deep learning-based computer-assisted detection software (EIRL aneurysm® [EIRL_an]), which has been approved by the Japanese Pharmaceuticals and Medical Devices Agency. We also sought to analyze the causes of potential false positives. METHODS: In this single-center, retrospective study, we evaluated the MRA scans of 90 patients who underwent head MRA (1.5 T and 3 T in 45 patients each) in clinical practice. Overall, 51 patients had 70 aneurysms. We used MRI from a vendor not included in the dataset used to create the EIRL_an algorithm. Two radiologists determined the ground truth, the accuracy of the candidates noted by EIRL_an, and the causes of false positives. The sensitivity, number of false positives per case (FPs/case), and the causes of false positives were compared between 1.5 T and 3 T MRA. Pearson's χ2 test, Fisher's exact test, and the Mann‒Whitney U test were used for the statistical analyses as appropriate. RESULTS: The sensitivity was high for 1.5 T and 3 T MRA (0.875‒1), but the number of FPs/case was significantly higher with 3 T MRA (1.511 vs. 2.578, p < 0.001). The most common causes of false positives (descending order) were the origin/bifurcation of vessels/branches, flow-related artifacts, and atherosclerosis and were similar between 1.5 T and 3 T MRA. CONCLUSION: EIRL_an detected significantly more false-positive lesions with 3 T than with 1.5 T MRA in this external validation study. Our data may help physicians with limited experience with MRA to correctly diagnose aneurysms using EIRL_an.


Assuntos
Aprendizado Profundo , Aneurisma Intracraniano , Humanos , Aneurisma Intracraniano/diagnóstico por imagem , Angiografia por Ressonância Magnética , Estudos Retrospectivos , Software , Computadores
11.
Medicine (Baltimore) ; 102(23): e33910, 2023 Jun 09.
Artigo em Inglês | MEDLINE | ID: mdl-37335676

RESUMO

To compare the quality and interobserver agreement in the evaluation of lumbar spinal stenosis (LSS) on computed tomography (CT) images between deep-learning reconstruction (DLR) and hybrid iterative reconstruction (hybrid IR). This retrospective study included 30 patients (age, 71.5 ± 12.5 years; 20 men) who underwent unenhanced lumbar CT. Axial and sagittal CT images were reconstructed using hybrid IR and DLR. In the quantitative analysis, a radiologist placed regions of interest within the aorta and recorded the standard deviation of the CT attenuation (i.e., quantitative image noise). In the qualitative analysis, 2 other blinded radiologists evaluated the subjective image noise, depictions of structures, overall image quality, and degree of LSS. The quantitative image noise in DLR (14.8 ± 1.9/14.2 ± 1.8 in axial/sagittal images) was significantly lower than that in hybrid IR (21.4 ± 4.4/20.6 ± 4.0) (P < .0001 for both, paired t test). Subjective image noise, depictions of structures, and overall image quality were significantly better with DLR than with hybrid IR (P < .006, Wilcoxon signed-rank test). Interobserver agreements in the evaluation of LSS (with 95% confidence interval) were 0.732 (0.712-0.751) and 0.794 (0.781-0.807) for hybrid IR and DLR, respectively. DLR provided images with improved quality and higher interobserver agreement in the evaluation of LSS in lumbar CT than hybrid IR.


Assuntos
Aprendizado Profundo , Estenose Espinal , Masculino , Humanos , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Estenose Espinal/diagnóstico por imagem , Estudos Retrospectivos , Tomografia Computadorizada por Raios X/métodos , Região Lombossacral , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Algoritmos , Doses de Radiação
12.
Radiographics ; 43(6): e220133, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-37200221

RESUMO

Deep learning has been recognized as a paradigm-shifting tool in radiology. Deep learning reconstruction (DLR) has recently emerged as a technology used in the image reconstruction process of MRI, which is an essential procedure in generating MR images. Denoising, which is the first DLR application to be realized in commercial MRI scanners, improves signal-to-noise ratio. When applied to lower magnetic field-strength scanners, the signal-to-noise ratio can be increased without extending the imaging time, and image quality is comparable to that of higher-field-strength scanners. Shorter imaging times decrease patient discomfort and reduce MRI scanner running costs. The incorporation of DLR into accelerated acquisition imaging techniques, such as parallel imaging or compressed sensing, shortens the reconstruction time. DLR is based on supervised learning using convolutional layers and is divided into the following three categories: image domain, k-space learning, and direct mapping types. Various studies have reported other derivatives of DLR, and several have shown the feasibility of DLR in clinical practice. Although DLR efficiently reduces Gaussian noise from MR images, denoising makes image artifacts more prominent, and a solution to this problem is desired. Depending on the training of the convolutional neural network, DLR may change the imaging features of lesions and obscure small lesions. Therefore, radiologists may need to adopt the habit of questioning whether any information has been lost on images that appear clean. ©RSNA, 2023 Quiz questions for this article are available in the supplemental material.


Assuntos
Aprendizado Profundo , Radiologia , Humanos , Imageamento por Ressonância Magnética , Redes Neurais de Computação , Radiologistas , Interpretação de Imagem Radiográfica Assistida por Computador , Algoritmos
13.
Can Assoc Radiol J ; 74(4): 688-694, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37041699

RESUMO

Purpose: To evaluate the effects of deep learning reconstruction (DLR) on image quality of abdominal computed tomography (CT) in patients without arm elevation compared with hybrid-iterative reconstruction (Hybrid-IR) and filtered back projection (FBP). Methods: In this retrospective study, axial images of 26 patients who underwent CT without arm elevation were reconstructed using DLR, Hybrid-IR, and FBP. Streak artifact index (SAI) was calculated by dividing the standard deviation of CT attenuation in the liver or spleen by that in fat. Two other blinded radiologists evaluated streak artifacts on images (in the liver, spleen, and kidney), depiction of liver vessels, subjective image noise, and overall quality. They were also asked to detect space-occupying lesions other than cysts in the liver, spleen, and kidney. Results: The SAI (liver/spleen) in DLR images was significantly reduced compared with Hybrid-IR and FBP. Regarding qualitative image analysis, streak artifacts in the 3 organs, qualitative image noise, and overall quality in DLR images were rated by both readers as significantly improved compared with Hybrid-IR (P ≤ .012) and FBP (P < .001). Both blinded readers detected more lesions on DLR images than on Hybrid-IR and FBP ones. Conclusion: DLR resulted in significantly better-quality abdominal CT images in patients scanned without elevating their arms with reducing streak artifacts compared with Hybrid-IR and FBP.


Assuntos
Braço , Aprendizado Profundo , Humanos , Estudos Retrospectivos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Doses de Radiação , Tomografia Computadorizada por Raios X/métodos , Algoritmos
14.
Br J Radiol ; 96(1150): 20220685, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37000686

RESUMO

OBJECTIVE: To investigate the effectiveness of a deep learning model in helping radiologists or radiology residents detect esophageal cancer on contrast-enhanced CT images. METHODS: This retrospective study included 250 and 25 patients with and without esophageal cancer, respectively, who underwent contrast-enhanced CT between December 2014 and May 2021 (mean age, 67.9 ± 10.3 years; 233 men). A deep learning model was developed using data from 200 and 25 patients with esophageal cancer as training and validation data sets, respectively. The model was then applied to the test data set, consisting of additional 25 and 25 patients with and without esophageal cancer, respectively. Four readers (one radiologist and three radiology residents) independently registered the likelihood of malignant lesions using a 3-point scale in the test data set. After the scorings were completed, the readers were allowed to reference to the deep learning model results and modify their scores, when necessary. RESULTS: The area under the curve (AUC) of the deep learning model was 0.95 and 0.98 in the image- and patient-based analyses, respectively. By referencing to the deep learning model results, the AUCs for the readers were improved from 0.96/0.93/0.96/0.93 to 0.97/0.95/0.99/0.96 (p = 0.100/0.006/<0.001/<0.001, DeLong's test) in the image-based analysis, with statistically significant differences noted for the three less-experienced readers. Furthermore, the AUCs for the readers tended to improve from 0.98/0.96/0.98/0.94 to 1.00/1.00/1.00/1.00 (p = 0.317/0.149/0.317/0.073, DeLong's test) in the patient-based analysis. CONCLUSION: The deep learning model mainly helped less-experienced readers improve their performance in detecting esophageal cancer on contrast-enhanced CT. ADVANCES IN KNOWLEDGE: A deep learning model could mainly help less-experienced readers to detect esophageal cancer by improving their diagnostic confidence and diagnostic performance.


Assuntos
Aprendizado Profundo , Neoplasias Esofágicas , Radiologia , Masculino , Humanos , Pessoa de Meia-Idade , Idoso , Estudos Retrospectivos , Radiologia/educação , Radiologistas , Tomografia Computadorizada por Raios X/métodos , Neoplasias Esofágicas/diagnóstico por imagem
15.
Jpn J Radiol ; 41(8): 863-871, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-36862290

RESUMO

PURPOSE: The aim of this study was to assess the impact of the deep learning reconstruction (DLR) with single-energy metal artifact reduction (SEMAR) (DLR-S) technique in pelvic helical computed tomography (CT) images for patients with metal hip prostheses and compare it with DLR and hybrid iterative reconstruction (IR) with SEMAR (IR-S). MATERIALS AND METHODS: This retrospective study included 26 patients (mean age 68.6 ± 16.6 years, with 9 males and 17 females) with metal hip prostheses who underwent a CT examination including the pelvis. Axial pelvic CT images were reconstructed using DLR-S, DLR, and IR-S. In one-by-one qualitative analyses, two radiologists evaluated the degree of metal artifacts, noise, and pelvic structure depiction. In side-by-side qualitative analyses (DLR-S vs. IR-S), the two radiologists evaluated metal artifacts and overall quality. By placing regions of interest on the bladder and psoas muscle, the standard deviations of their CT attenuation were recorded, and the artifact index was calculated based on them. Results were compared between DLR-S vs. DLR and DLR vs. IR-S using the Wilcoxon signed-rank test. RESULTS: In one-by-one qualitative analyses, metal artifacts and structure depiction in DLR-S were significantly better than those in DLR; however, between DLR-S and IR-S, significant differences were noted only for reader 1. Image noise in DLR-S was rated as significantly reduced compared with that in IR-S by both readers. In side-by-side analyses, both readers rated that the DLR-S images are significantly better than IR-S images regarding overall image quality and metal artifacts. The median (interquartile range) of the artifact index for DLR-S was 10.1 (4.4-16.0) and was significantly better than those for DLR (23.1, 6.5-36.1) and IR-S (11.4, 7.8-17.9). CONCLUSION: DLR-S provided better pelvic CT images in patients with metal hip prostheses than IR-S and DLR.


Assuntos
Aprendizado Profundo , Prótese de Quadril , Masculino , Feminino , Humanos , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Artefatos , Estudos Retrospectivos , Algoritmos , Tomografia Computadorizada por Raios X/métodos , Metais , Pelve
16.
J Comput Assist Tomogr ; 47(4): 583-589, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36877787

RESUMO

OBJECTIVE: This study aimed to investigate the impact of deep-learning reconstruction (DLR) on the detailed evaluation of solitary lung nodule using high-resolution computed tomography (HRCT) compared with hybrid iterative reconstruction (hybrid IR). METHODS: This retrospective study was approved by our institutional review board and included 68 consecutive patients (mean ± SD age, 70.1 ± 12.0 years; 37 men and 31 women) who underwent computed tomography between November 2021 and February 2022. High-resolution computed tomography images with a targeted field of view of the unilateral lung were reconstructed using filtered back projection, hybrid IR, and DLR, which is commercially available. Objective image noise was measured by placing the regions of interest on the skeletal muscle and recording the SD of the computed tomography attenuation. Subjective image analyses were performed by 2 blinded radiologists taking into consideration the subjective noise, artifacts, depictions of small structures and nodule rims, and the overall image quality. In subjective analyses, filtered back projection images were used as controls. Data were compared between DLR and hybrid IR using the paired t test and Wilcoxon signed-rank sum test. RESULTS: Objective image noise in DLR (32.7 ± 4.2) was significantly reduced compared with hybrid IR (35.3 ± 4.4) ( P < 0.0001). According to both readers, significant improvements in subjective image noise, artifacts, depictions of small structures and nodule rims, and overall image quality were observed in images derived from DLR compared with those from hybrid IR ( P < 0.0001 for all). CONCLUSIONS: Deep-learning reconstruction provides a better high-resolution computed tomography image with improved quality compared with hybrid IR.


Assuntos
Aprendizado Profundo , Masculino , Humanos , Feminino , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Estudos Retrospectivos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Algoritmos , Doses de Radiação , Tomografia Computadorizada por Raios X/métodos , Pulmão , Processamento de Imagem Assistida por Computador/métodos
17.
Int J Hematol ; 118(1): 135-140, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-36735218

RESUMO

Plasma cell leukemia is a rare yet aggressive form of multiple myeloma characterized by high levels of plasma cells circulating in the peripheral blood. We recently experienced a case of plasma cell leukemia that had been in stringent complete remission for nine years after autologous stem cell transplantations with subsequent courses of lenalidomide maintenance therapy, and then relapsed as an extramedullary plasmacytoma in the central nervous system. Assessment of the bone marrow did not prove proliferation of plasma cells at relapse, but imbalanced elevation of serum levels of free light chains was observed without changes in other clinical biomarkers including immunoglobulin levels. Salvage chemotherapy with isatuximab, pomalidomide, and dexamethasone (IsaPD) was promptly initiated. After two courses of IsaPD, significant remission was achieved and the neuronal symptoms completely resolved. When excessive serum levels of clonotypic free light chains are noted, their significance should be carefully assessed even when plasma cell propagation in the bone marrow is not observed. In such cases, hematologists should search for extramedullary proliferation of plasma cells, including in the immune-privileged central nervous system.


Assuntos
Transplante de Células-Tronco Hematopoéticas , Leucemia Plasmocitária , Mieloma Múltiplo , Humanos , Leucemia Plasmocitária/diagnóstico , Leucemia Plasmocitária/terapia , Mieloma Múltiplo/tratamento farmacológico , Recidiva , Sistema Nervoso Central , Protocolos de Quimioterapia Combinada Antineoplásica/uso terapêutico
18.
Abdom Radiol (NY) ; 48(4): 1280-1289, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36757454

RESUMO

PURPOSE: This study aimed to compare the hepatocellular carcinoma (HCC) detection performance, interobserver agreement for Liver Imaging Reporting and Data System (LI-RADS) categories, and image quality between deep learning reconstruction (DLR) and conventional hybrid iterative reconstruction (Hybrid IR) in CT. METHODS: This retrospective study included patients who underwent abdominal dynamic contrast-enhanced CT between October 2021 and March 2022. Arterial, portal, and delayed phase images were reconstructed using DLR and Hybrid IR. Two blinded readers independently read the image sets with detecting HCCs, scoring LI-RADS, and evaluating image quality. RESULTS: A total of 26 patients with HCC (mean age, 73 years ± 12.3) and 23 patients without HCC (mean age, 66 years ± 14.7) were included. The figures of merit (FOM) for the jackknife alternative free-response receiver operating characteristic analysis in detecting HCC averaged for the readers were 0.925 (reader 1, 0.937; reader 2, 0.913) in DLR and 0.878 (reader 1, 0.904; reader 2, 0.851) in Hybrid IR, and the FOM in DLR were significantly higher than that in Hybrid IR (p = 0.038). The interobserver agreement (Cohen's weighted kappa statistics) for LI-RADS categories was moderate for DLR (0.595; 95% CI, 0.585-0.605) and significantly superior to Hybrid IR (0.568; 95% CI, 0.553-0.582). According to both readers, DLR was significantly superior to Hybrid IR in terms of image quality (p ≤ 0.021). CONCLUSION: DLR improved HCC detection, interobserver agreement for LI-RADS categories, and image quality in evaluations of HCC compared to Hybrid IR in abdominal dynamic contrast-enhanced CT.


Assuntos
Carcinoma Hepatocelular , Neoplasias Hepáticas , Fígado , Humanos , Idoso , Carcinoma Hepatocelular/diagnóstico por imagem , Carcinoma Hepatocelular/patologia , Fígado/diagnóstico por imagem , Variações Dependentes do Observador , Aprendizado Profundo , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/patologia , Tomografia por Raios X , Masculino , Feminino , Pessoa de Meia-Idade , Idoso de 80 Anos ou mais
19.
BMC Med Imaging ; 23(1): 5, 2023 01 09.
Artigo em Inglês | MEDLINE | ID: mdl-36624404

RESUMO

PURPOSE: To evaluate whether deep learning reconstruction (DLR) accelerates the acquisition of 1.5-T magnetic resonance imaging (MRI) knee data without image deterioration. MATERIALS AND METHODS: Twenty-one healthy volunteers underwent MRI of the right knee on a 1.5-T MRI scanner. Proton-density-weighted images with one or four numbers of signal averages (NSAs) were obtained via compressed sensing, and DLR was applied to the images with 1 NSA to obtain 1NSA-DLR images. The 1NSA-DLR and 4NSA images were compared objectively (by deriving the signal-to-noise ratios of the lateral and the medial menisci and the contrast-to-noise ratios of the lateral and the medial menisci and articular cartilages) and subjectively (in terms of the visibility of the anterior cruciate ligament, the medial collateral ligament, the medial and lateral menisci, and bone) and in terms of image noise, artifacts, and overall diagnostic acceptability. The paired t-test and Wilcoxon signed-rank test were used for statistical analyses. RESULTS: The 1NSA-DLR images were obtained within 100 s. The signal-to-noise ratios (lateral: 3.27 ± 0.30 vs. 1.90 ± 0.13, medial: 2.71 ± 0.24 vs. 1.80 ± 0.15, both p < 0.001) and contrast-to-noise ratios (lateral: 2.61 ± 0.51 vs. 2.18 ± 0.58, medial 2.19 ± 0.32 vs. 1.97 ± 0.36, both p < 0.001) were significantly higher for 1NSA-DLR than 4NSA images. Subjectively, all anatomical structures (except bone) were significantly clearer on the 1NSA-DLR than on the 4NSA images. Also, in the former images, the noise was lower, and the overall diagnostic acceptability was higher. CONCLUSION: Compared with the 4NSA images, the 1NSA-DLR images exhibited less noise, higher overall image quality, and allowed more precise visualization of the menisci and ligaments.


Assuntos
Aprendizado Profundo , Humanos , Articulação do Joelho/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Razão Sinal-Ruído , Aceleração
20.
Magn Reson Med Sci ; 22(3): 353-360, 2023 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-35811127

RESUMO

PURPOSE: This study aimed to evaluate whether the image quality of 1.5T magnetic resonance imaging (MRI) of the knee is equal to or higher than that of 3T MRI by applying deep learning reconstruction (DLR). METHODS: Proton density-weighted images of the right knee of 27 healthy volunteers were obtained by 3T and 1.5T MRI scanners using similar imaging parameters (21 for high resolution image and 6 for normal resolution image). Commercially available DLR was applied to the 1.5T images to obtain 1.5T/DLR images. The 3T and 1.5T/DLR images were compared subjectively for visibility of structures, image noise, artifacts, and overall diagnostic acceptability and objectively. One-way ANOVA and Friedman tests were used for the statistical analyses. RESULTS: For the high resolution images, all of the anatomical structures, except for bone, were depicted significantly better on the 1.5T/DLR compared with 3T images. Image noise scored statistically lower and overall diagnostic acceptability scored higher on the 1.5T/DLR images. The contrast between lateral meniscus and articular cartilage of the 1.5T/DLR images was significantly higher (5.89 ± 1.30 vs. 4.34 ± 0.87, P < 0.001), and also the contrast between medial meniscus and articular cartilage of the 1.5T/DLR images was significantly higher (5.12 ± 0.93 vs. 3.87 ± 0.56, P < 0.001). Similar image quality improvement by DLR was observed for the normal resolution images. CONCLUSION: The 1.5T/DLR images can achieve less noise, more precise visualization of the meniscus and ligaments, and higher overall image quality compared with the 3T images acquired using a similar protocol.


Assuntos
Cartilagem Articular , Aprendizado Profundo , Humanos , Voluntários Saudáveis , Imageamento por Ressonância Magnética/métodos , Articulação do Joelho/diagnóstico por imagem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...